Shelly S4SW-002P16EU: Relay resets, drops Wi-Fi, or sticks closed when switching motors/fans/LED drivers
What this means: MCU instability or contact damage caused by high-voltage transients from inductive loads.
60-Second Verification Check
Verify if an RC Snubber is installed in parallel with the inductive load.
Verified Replacement Parts
RC Snubber (Inductive Load Suppressor)
Matches manufacturer's specified electrical values for inductive load suppression.
Complete Relay Module (EU / UL)
Proprietary firmware and form factor require OEM replacement.
Why This Happens & Safety Warnings
- Do not open or modify the factory-sealed housing; opening voids UL/CE compliance and the 3-year warranty.
What triggers it: Switching inductive motors, fans, or high-inrush LED drivers without an RC snubber.
What wears out inside: High-voltage switching arc causes contact pitting, erosion, or welding closed.
Symptom on machine: Relay fails to switch (stuck ON/OFF), intermittent operation, or device reboot.
Cross-Compatible Platforms: RC Snubber electrical specification (0.1 µF / 100 Ω / 0.5 W / 600 VAC) and resistive/capacitive/inductive load guidance derived from Shelly Plus 2PM / Pro 2PM engineering documentation.