Shelly SNDM-0013US: LED bar never illuminates after breaker on
What this means: Dimmer unit appears completely dead, indicating no power or a critical internal failure.
60-Second Verification Check
Verify 120V AC between Line and Neutral with a multimeter; check for missing neutral wire or Line/Load reversal.
Verified Replacement Parts
Replacement Dimmer Unit (SNDM-0013US)
Exact replacement for one unit of the 2-pack bundle.
Why This Happens & Safety Warnings
What triggers it: Continuous 24/7 operation of ESP32 Wi-Fi radio, generating heat in an enclosed wallbox.
What wears out inside: Gradual electrolytic capacitor Equivalent Series Resistance (ESR) rise due to thermal stress.
Symptom on machine: Intermittent power supply to the ESP32, leading to device instability, reboot loops, or complete failure.
What triggers it: Utility power surge, lightning strike, or shorted lighting load.
What wears out inside: Overvoltage/overcurrent transient exceeds MOSFET junction breakdown voltage or surge protection capacity, causing permanent damage.
Symptom on machine: Dimmer fails in a permanently 'on' state, 'off' state (dead load), or becomes unresponsive.
Cross-Compatible Platforms: Shelly Gen2 "Plus" ESP32 firmware ecosystem (local web UI, MQTT, webhooks, mJS scripting, Home Assistant native integration).