Shelly Wall Display XL: Random Reboots When Switching Load
What this means: Screen resets or Wi-Fi drops right as relay toggles an inductive load.
60-Second Verification Check
Test switching with load disconnected; if stable unloaded, install a Shelly-approved RC snubber across the inductive load or use an external contactor.
Verified Replacement Parts
RC Snubber (Inductive Load Suppressor)
Designed to suppress voltage spikes and arcing for inductive loads, protecting relay contacts and preventing EMI-induced reboots. Must be safety-rated (UL/ENEC X2).
External Pilot Contactor / Heavy Relay
Used to isolate high-amperage or multi-motor loads from the built-in 5A relay, switching the heavy load via the contactor's robust contacts.
Why This Happens & Safety Warnings
- Always de-energize the circuit breaker and verify zero voltage before wiring or detaching/attaching the display head.
What triggers it: Switching an unsnubbed inductive load (e.g., motor, fan) via the built-in relay.
What wears out inside: Inductive kickback (voltage spike) from the load couples into the compact SMPS power rail, causing a momentary voltage dip or transient that resets the embedded SoC/OS.
Symptom on machine: Touchscreen reboots or Wi-Fi temporarily disconnects, interrupting control and user experience.
Cross-Compatible Platforms: Shares Shelly Wall Display modular base-and-head architecture