Walfront WALFRONTtoenc8ig3q: Load stays permanently energized despite UI toggle; no audible click from relay
What this means: The hardwired lighting load remains ON regardless of the control panel's command, and the characteristic 'click' of the relay engaging/disengaging is absent.
60-Second Verification Check
Disconnect breaker and test continuity across L and L1; check if connected LED load exceeded inrush rating.
Verified Replacement Parts
Electromechanical Load Relay
Requires matching coil voltage, current rating, footprint, and safety certifications for AC mains switching.
Why This Happens & Safety Warnings
What triggers it: Switching high-inrush capacitive loads (e.g., modern LED drivers)
What wears out inside: High inrush currents cause arcing and localized heating, leading to pitting and eventual welding of silver-alloy relay contacts.
Symptom on machine: Hardwired lighting load remains permanently ON or OFF, unresponsive to control panel commands.
Cross-Compatible Platforms: Architecture aligned with Tuya 4-inch smart control panel family (TPP01/S6E class)