WiFi 852wf: Relay Stuck ON (Won't Turn Off)
What this means: Light/load stays energized even when app toggles OFF and LED changes state.
60-Second Verification Check
Disconnect breaker and check continuity across `L`-`L-out`; permanent continuity confirms welded contacts.
Verified Replacement Parts
Complete Replacement Mini Relay Module
Direct replacement of the entire SKU.
Why This Happens & Safety Warnings
- Because the internal AC-DC buck supply is non-isolated, the entire circuit board (including the Wi-Fi SoC ground) sits at live mains potential when energized; NEVER attach UART/FTDI cables while connected to AC mains.
What triggers it: Switching high-inrush LED drivers (>300W) or inductive motors.
What wears out inside: High current arcs across miniature relay contacts, causing contact faces to fuse closed.
Symptom on machine: Load remains permanently energized (stuck ON) or cannot be switched OFF.
Cross-Compatible Platforms: `ABS+PC` shell, `42x42x22 mm` dimensions, `300W` LED limit, and `-10°C to 45°C` envelope are anchored to `ngnsky` brand-family 16A mini relay specifications.