Wyze WSPRK1: Controller dark or zone fails to energize valve
What this means: The controller is unresponsive (dark) or a specific zone does not activate its irrigation valve.
60-Second Verification Check
Measure 24VAC at adapter output; if 0V, replace adapter. If 24VAC present at terminal, test valve solenoid resistance (typically 20–60 ohms).
Verified Replacement Parts
24V AC 1A Plug-In Power Supply
Matches the electrical output and physical connector requirements of the original supplied power adapter.
Why This Happens & Safety Warnings
What triggers it: Continuous 24/7 energization or grid voltage spikes.
What wears out inside: Degradation of internal components (e.g., capacitors, transformer windings) within the wall-wart transformer.
Symptom on machine: Controller becomes unresponsive due to lack of power.
What triggers it: Underground wire nick or shorted solenoid coil.
What wears out inside: Excess current draw over 24VAC rail, damaging solid-state switch (TRIAC).
Symptom on machine: Specific irrigation zone fails to energize its valve.
Cross-Compatible Platforms: Shares Wyze cloud/app ecosystem and Sprinkler Plus weather-skip subscription model.