Symptom Guide Model: WSPRK1

Wyze WSPRK1: Controller dark or zone fails to energize valve

What this means: The controller is unresponsive (dark) or a specific zone does not activate its irrigation valve.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Front panel yellow LEDs flashing. — This is a normal indicator after holding the rear Reset button for 10 seconds, signifying the unit is in a reset/pairing state and ready for re-pairing.

Measure 24VAC at adapter output; if 0V, replace adapter. If 24VAC present at terminal, test valve solenoid resistance (typically 20–60 ohms).

Target: 24VACTarget: 20–60 ohms
2

Verified Replacement Parts

#1 Most Likely Fix ~$15–$25 (Generic)

24V AC 1A Plug-In Power Supply

Class 2 Plug-In… Copy Part #

Matches the electrical output and physical connector requirements of the original supplied power adapter.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in smart wifi sprinkler controllers replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
External Power Adapter Failure

What triggers it: Continuous 24/7 energization or grid voltage spikes.

What wears out inside: Degradation of internal components (e.g., capacitors, transformer windings) within the wall-wart transformer.

Symptom on machine: Controller becomes unresponsive due to lack of power.

Zone Output Failure from Field Short

What triggers it: Underground wire nick or shorted solenoid coil.

What wears out inside: Excess current draw over 24VAC rail, damaging solid-state switch (TRIAC).

Symptom on machine: Specific irrigation zone fails to energize its valve.

Cross-Compatible Platforms: Shares Wyze cloud/app ecosystem and Sprinkler Plus weather-skip subscription model.