Observed Condition: Display shows 'E1'; unit refuses to heat. Indicates the tip-over safety switch has been activated or is faulty.
Immediate Non-Invasive Triage: Verify the unit is upright on a flat, level floor. If 'E1' persists, the tip-over switch may be stuck or failed.
Platform Cross-Reference: Electromechanically identical to White sibling TRD40615E (PID 0110838317); shares Dragon 4 manual safety rules, error codes (PF, E1), and internal electrical spares.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
5210810101 | Main Control Board (PCB) Proprietary PCB; OEM replacement ensures compatibility and safety. |
~$54.95 OEM | |
| Part 2 oem replacement part |
5210810111 | NTC Temperature Sensor OEM recommended due to specific resistance curve required for accurate temperature sensing. |
~$6.95 OEM | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified oil filled radiant space heaters replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Mechanical impact, repeated tip-overs, or internal component sticking.
Physics / Degradation: The internal tip-over switch mechanism becomes stuck in the 'open' position or fails to reset, even when the unit is upright.
System Lockout / Impact: Heater displays 'E1' error code and heating function is disabled.