Observed Condition: Display shows 'PF'; heating halts. Indicates an open or short circuit in the NTC temperature sensor.
Immediate Non-Invasive Triage: Unplug the unit for 30+ minutes to reset. If 'PF' persists, the NTC sensor or its harness is likely faulty.
Platform Cross-Reference: Electromechanically identical to White sibling TRD40615E (PID 0110838317); shares Dragon 4 manual safety rules, error codes (PF, E1), and internal electrical spares.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
5210810111 | NTC Temperature Sensor OEM recommended due to specific resistance curve required for accurate temperature sensing. |
~$6.95 OEM | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified oil filled radiant space heaters replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Repeated thermal cycling or mechanical stress on the sensor harness.
Physics / Degradation: NTC thermistor element drifts out of calibration, or its wiring harness develops an open/short circuit.
System Lockout / Impact: Heater displays 'PF' (Probe Failure) error code and heating function is disabled.