meross MTS200: Displayed Room Temp Reads 1.5°C–3°C High Under Heavy 16A Load
What this means: Room temperature climbs slightly higher than an external room thermometer while electric floor mat runs continuously.
60-Second Verification Check
Apply a negative calibration offset (e.g., '-1.5°C') in the Meross calibration menu once steady-state is verified.
Verified Replacement Parts
External Modular DIN Contactor (For >16A Loads)
Expands load capacity beyond the thermostat's internal relay, preventing overload and overheating. Must be correctly rated for voltage and current.
Why This Happens & Safety Warnings
- Isolate Mains Circuit Breaker Before Installation
What triggers it: Continuous high-current electric heating load (14A–16A)
What wears out inside: Insufficient screw torque or frayed stranded wire creates localized contact resistance, leading to I^2R heating and thermal stress on terminal plastics and relay.
Symptom on machine: Thermal discoloration of terminals, potential for fire hazard, intermittent heating, or complete relay failure.
Cross-Compatible Platforms: Shares the Meross Matter-over-Wi-Fi 2.4 GHz provisioning stack and tempered glass capacitive touch UI with the MTS200MA / MTS200HK / MTS200B series.