CMA Dishmachines UC65E: Overheat / No Heat in Wash or Booster Tank
What this means: Water stays lukewarm (<140°F wash or <175°F rinse).
60-Second Verification Check
With power LOCKED OUT, test continuity across the manual-reset hi-limit safety thermostat on the affected tank (often trips if scale blankets the element or if the air-trap allowed a low-water fill).
Verified Replacement Parts
6.5 kW Booster Immersion Heating Element
Must match voltage, wattage, material (Incoloy), and physical dimensions for safe and effective operation.
2.1 kW Wash Tank Immersion Heating Element
Must match voltage, wattage, material (Incoloy), and physical dimensions for safe and effective operation.
Why This Happens & Safety Warnings
- Do not use chlorine bleach sanitizers.
- Ensure power is LOCKED OUT before performing any electrical service or continuity tests.
What triggers it: Operation in hard water (>3 gpg)
What wears out inside: High surface watt density (6.5 kW) at 185°F–195°F precipitates calcium carbonate scale rapidly, insulating the Incoloy sheath.
Symptom on machine: Reduced heating efficiency, manual-reset hi-limit trips, or element splits, leading to no hot rinse and sanitization failure.
What triggers it: Repeated high-current switching of heating elements
What wears out inside: Arc erosion on contactor contacts or thermal loosening at main terminal lugs due to high amperage (35.5A–39.5A).
Symptom on machine: Failure of heating elements to energize, leading to cold wash/rinse temperatures and sanitization failure.
Cross-Compatible Platforms: Shares electronic soft-touch 3-cycle control topology and deep-drawn coved tank architecture with the CMA UC50e / Ali Group compact electronic undercounter family.