FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: UC65E TIER 1–2 BENCH DIY

CMA Dishmachines UC65E: Safe-T-Temp Cycle Hold Extension

⚡ Bench Triage & Meter Telemetry
120°F180°F208-240V

01 // Observed Condition

Wash phase continues running past 120 seconds before final rinse triggers.

02 // Non-Invasive Meter / Bench Verification

Check digital rinse temp readout and incoming hot-water line temp. If incoming water is <120°F, Safe-T-Temp holds the cycle until the booster reaches 180°F. If booster never heats, check the manual-reset red button on the booster hi-limit thermostat and verify 208-240V across the 6.5 kW element.

Platform / OEM Cross-Reference: Shares electronic soft-touch 3-cycle control topology and deep-drawn coved tank architecture with the CMA UC50e / Ali Group compact electronic undercounter family.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
208-240V 6,500W (@ 240V)… 6.5 kW Booster Immersion Heating Element
Must match voltage, wattage, material (Incoloy), and physical dimensions for safe and effective operation.
$145–$215 (OEM)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial undercounter dishwashers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:IncoloyIncoloy 800NTCStainless SteelTRIACVITON

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not use chlorine bleach sanitizers.
  • Ensure power is LOCKED OUT before performing any electrical service or continuity tests.

Root Failure Mechanism: 6.5 kW Booster Element Scale Encrustation & Hi-Limit CutoffClick to spotlight part ↑

01 // Trigger ConditionOperation in hard water (>3 gpg)
02 // Degradation PhysicsHigh surface watt density (6.5 kW) at 185°F–195°F precipitates calcium carbonate scale rapidly, insulating the Incoloy sheath.
03 // Lockout / ImpactReduced heating efficiency, manual-reset hi-limit trips, or element splits, leading to no hot rinse and sanitization failure.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — 1–2 second gradual ramp-up of wash pump pressure at start of every cycle: The wash pump intentionally ramps speed smoothly over the first ~2 seconds rather than slamming on at full torque. (True fault when: If the pump fails to reach full pressure after the initial ramp-up, or if the ramp-up takes significantly longer than 2 seconds.)

Other CMA Dishmachines UC65E Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...