CMA Dishmachines UC65E: Safe-T-Temp Cycle Hold Extension
⚡ Bench Triage & Meter Telemetry
120°F180°F208-240V
01 // Observed Condition
Wash phase continues running past 120 seconds before final rinse triggers.
02 // Non-Invasive Meter / Bench Verification
Check digital rinse temp readout and incoming hot-water line temp. If incoming water is <120°F, Safe-T-Temp holds the cycle until the booster reaches 180°F. If booster never heats, check the manual-reset red button on the booster hi-limit thermostat and verify 208-240V across the 6.5 kW element.
Platform / OEM Cross-Reference: Shares electronic soft-touch 3-cycle control topology and deep-drawn coved tank architecture with the CMA UC50e / Ali Group compact electronic undercounter family.