UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: BIDW1802BL

EdgeStar BIDW1802BL: E7

Observed Condition: NTC thermistor short circuit fault: Main control PCB detects a short circuit across the sump water temperature sensor leads.

Immediate Non-Invasive Triage: Requires qualified technician resistance check (nominal 10 kOhm at 25°C, 3011 Ohm at 60°C) and inspection for moisture intrusion in the underpan thermistor connector.

Platform Cross-Reference: Electromechanically identical to BIDW1802SS and BIDW1802WH

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
NTC thermistor probe… Sump NTC Water Temperature Thermistor Probe
Sourced from EdgeStar BIDW1802 Service Manual resistance table; resistance curve must match exactly, as generic 50 kOhm sensors will trigger E6/E7 or thermal regulation errors.
$15-$30
Part 2
universal aftermarket part
120 V AC, 700 W tubular… 700 W Tubular Resistive Water Heating Element
Sourced from EdgeStar Owner's Manual and Service Manual; must verify terminal stud spacing through the 304 stainless steel tub floor and watertight O-ring compression gaskets.
$45-$80
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified 18 inch compact built in undercounter dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Disconnect electrical power at the circuit breaker or power source before removing the kick plate, accessing the internal junction box, or servicing any underpan components.
  • Never bypass or defeat the bottom drip pan safety float microswitch to clear an E4 error code while water remains in the pan.

Root Mechanism: 700 W Tubular Heating Element Limescale Encrustation, Sheath Burnout, or NTC Drift (E3/E6/E7)

Trigger: Operation in hard municipal water without periodic citric-acid descaling, or excessively cold inlet water (<100°F) demanding prolonged element energization.

Physics / Degradation: Calcareous scale blankets the 700 W resistive heating element sheath and sump NTC thermistor probe; scale acts as a thermal insulator that slows heat transfer into the wash water (exceeding the 90-minute heating window) and drives internal element core temperatures until the resistive filament burns open.

System Lockout / Impact: Loss of water heating, sanitization (156°F), and supplemental heated drying, accompanied by E3 heating timeout faults (or E6/E7 if the NTC thermistor opens or shorts).

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Plastic containers, Tupperware, and lightweight polymers remain covered in water droplets at the end of a wash and dry cycle while ceramic and glass items are dry.: The appliance uses passive condensation drying supplemented by the 700 W water/radiant heating element and lacks a motorized forced-air blower fan. The 304 stainless steel tub cools faster than hot ceramic dishes to condense moisture onto the tub walls, whereas low-thermal-mass plastics cool rapidly and cannot shed water without surfactant rinse aid and post-cycle door venting. (True fault when: Indicates an actual fault only if wash/rinse water never heats during the cycle, ceramic dishes also remain cold and wet, or diagnostic code E3 is triggered.)
False-Alarm Check — A warm asphalt, tar, or chemical odor emanates from the cabinet enclosure during the first 1 to 3 heated wash cycles.: The outer walls of the 304 stainless steel tub are bonded with a bituminous asphaltic mastic blanket for 52 dBA acoustic damping, which exhibits minor thermal outgassing during initial high-temperature cycles (140°F–156°F). (True fault when: Indicates a fault if accompanied by visible smoke, acrid burnt-electronics odor from the console/kick plate, tripped branch circuit breakers, or persistent odor beyond break-in cycles.)

Other EdgeStar BIDW1802BL Fault Signals