EdgeStar BIDW1802BL: Wash circulation motor hums or remains silent after water fill with zero spray arm rotation
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Dishwasher completes timed water intake and drains on command, but the 100 W induction wash pump fails to circulate water, either emitting a 60 Hz stall hum or remaining completely silent.
02 // Non-Invasive Meter / Bench Verification
Remove and inspect the sump triple filter assembly for foreign debris and verify spray arm nozzles are unobstructed; technicians use the 4-step factory diagnostic test mode (holding Rinse and Start/Cancel within 60s of power-on with door unlatched) to isolate motor stall vs. PCB relay dropout.
Platform / OEM Cross-Reference: Electromechanically identical to BIDW1802SS and BIDW1802WH