Observed Condition: Water fill timeout aborting cycle during initial fill phase (flow meter registers inadequate pulses after 4 minutes).
Immediate Non-Invasive Triage: Check water supply valve shutoff, clean inlet valve wire mesh screen, and verify water pressure.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
120 V, 60 Hz, ~1.0 kOhm… | Water Inlet Solenoid Valve Midea platform standard electrical and mechanical interface compatibility. |
$28.00-$45.00 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified built in dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Municipal sediment, sand, or pipe scale in water supply lines
Physics / Degradation: Silt clogs fine inlet wire screen; water inflow volume drops below threshold during fill phase
System Lockout / Impact: Machine halts 4 minutes into wash program with E1 error code