UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: BIDW1802WH

EdgeStar BIDW1802WH: E3

Observed Condition: Heating failure or cycle stalls before drying due to water failing to reach target temperature within 90 minutes.

Immediate Non-Invasive Triage: Test NTC thermistor resistance and check heating element circuit continuity.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
10 kOhm @ 25C, 3.01 kOhm… Sump NTC Thermistor
Temperature-resistance curve matches factory table.
$18.00-$30.00
Part 2
oem replacement part
120 V AC, ~800 W sheathed… Immersion Heating Element
Exact electrical load and geometry match for BIDW1802 basin.
$45.00-$70.00
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified built in dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Disconnect branch circuit electrical service at main breaker before opening electrical junction box; line voltage remains present at PCB connector CN6 Pin 1 when door is unlatched.

Root Mechanism: E3 Thermal Lockout from Mineral Scaling

Trigger: Hard water scale deposition exceeding normal residential thresholds

Physics / Degradation: Thick mineral encrustation insulates heater sheath, delaying heat transfer; PCB safety timer aborts cycle at 90 minutes

System Lockout / Impact: Lukewarm wash cycles, grease deposition, and aborted cycle runs with E3 error

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — LSb displayed on front digital control fascia.: LSb denotes Low Substance (low rinse aid level) and clears upon refilling the liquid rinse aid dispenser reservoir. (True fault when: If the indicator remains lit immediately after completely filling the reservoir with rinse aid, indicating a stuck optical reed sensor.)
False-Alarm Check — Residual water droplets remaining on plastic dishware after cycle completion.: Plasticware lacks thermal mass to flash off moisture effectively without rinse aid and the Heated Dry option, which is inherent to compact condensing-dryer architecture. (True fault when: If metal and ceramic dishware also remain thoroughly wet or cold, or if the heating element fails to energize during the drying phase.)

Other EdgeStar BIDW1802WH Fault Signals