Fisher & Paykel DD24DV2T9: Error Code F4 (Flow-Through Heating Element Fault)

Observed Condition: Open circuit or heating failure in the sump thick-film flow-through water heating element.

Immediate Non-Invasive Triage: Observe whether wash cycles run cold and fail to complete Sanitize rinse heating; route to a qualified technician for heater continuity testing and sump plate replacement.

Platform Cross-Reference: Motorized lid sealing architecture: Dual electric actuators (PN 524177P / 524178P) vertically lower an elastomeric-gasketed lid onto each polymer tub rim upon drawer closure across the DD24 platform.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
524922P SmartDrive Motor Rotor & Impeller Assembly
Confirmed OEM replacement part for DD24DV2T9; genuine OEM rotor is recommended because aftermarket clones may vary in permanent magnet flux and impeller blade geometry.
$105.95 - $137.11 USD; ~$21 - $48 USD
Part 2
oem replacement part
510727 Sump Rotor Silicone O-Ring Seal
Factory-specified silicone O-ring seal for the DishDrawer SmartDrive rotor sump well; mandatory replacement during rotor service to prevent sump leaks into the base pan.
$3.95 NZD / ~$3.00 USD
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified dishwashers replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not operate the DishDrawer dishwasher unless the motor rotor assembly, perforated stainless steel filter plate, cylindrical drain filter, and spray arm are all properly seated and locked in place, as unshielded debris can damage internal pump hydraulics.
  • Do not pinch opposing sides of the cylindrical drain filter mesh simultaneously during removal or cleaning, as this can fracture the plastic support ring.

Root Mechanism: Flow-Through Thick-Film Heater Scale Burnout (F4) or Thermistor Fault (F3)

Trigger: Extended operation in hard water (>180 ppm) without periodic descaling (given the absence of an internal water softener), or exposure to inlet water >140°F.

Physics / Degradation: Calcium carbonate mineral scale forms an insulating layer over the stainless sump plate, impeding heat transfer into the wash water and causing localized thermal hotspot burnout of the printed thick-film heater element (F4) or thermistor drift (F3).

System Lockout / Impact: Wash cycles run cold, grease removal degrades, Sanitize cycles fail to reach >=140°F, and error codes F3 or F4 halt operation.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Warm, humid air venting from the concealed lower toe-kick / kickstrip area during and after the wash cycle.: The DD24DV2T9 uses a 12V DC centrifugal blower to actively extract moist vapor from the wash chamber and exhaust it through a concealed lower kickstrip vent during the drying phase. (True fault when: Indicates a fault only if liquid water pools on the floor, steam escapes around the upper drawer perimeter due to a torn lid gasket, or the F1 flood switch trips.)
False-Alarm Check — Brief mechanical whirring sound and pause after closing a drawer before cycle start, or before the drawer can be pulled open at cycle end.: Dual electric lid actuator motors vertically lower the rigid perimeter sealing lid onto the polymer tub rim after drawer closure and lift it clear when the cycle finishes or pauses. (True fault when: Indicates an obstruction or actuator failure if accompanied by grinding gear noise, inability to open/close the drawer, or error codes F52 / U3.)

Other Fisher & Paykel DD24DV2T9 Fault Signals