FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: DD24DV2T9 TIER 1–2 BENCH DIY

Fisher & Paykel DD24DV2T9: Intermittent Drainage / Standing Water Pooled in Tub Sump

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Wastewater remains pooled in the bottom of the wash tub at the end of a cycle with or without an accompanying F2 error code.

02 // Non-Invasive Meter / Bench Verification

Clean the cylindrical drain filter mesh and stainless sump filter plate; if drainage only fails when the drawer is pushed fully closed, inspect for drain hose kinking inside the rear umbilical caterpillar track or debris binding the SmartDrive rotor.

Platform / OEM Cross-Reference: Motorized lid sealing architecture: Dual electric actuators (PN 524177P / 524178P) vertically lower an elastomeric-gasketed lid onto each polymer tub rim upon drawer closure across the DD24 platform.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
524922P SmartDrive Motor Rotor & Impeller Assembly
Confirmed OEM replacement part for DD24DV2T9; genuine OEM rotor is recommended because aftermarket clones may vary in permanent magnet flux and impeller blade geometry.
$105.95 - $137.11 USD; ~$21 - $48 USD
Part 2
oem replacement part
Isolated Match
524783 Cylindrical Drain Filter Mesh Assembly
Quarter-turn twist-lock fine mesh filter assembly; exact part number must be matched to the unit's engineering revision code (71401-A vs. 82345-A/B or 82756-A).
Approx. $22 - $35 USD
Part 3
oem replacement part
Isolated Match
Series 9 Twin Articulated… Series 9 Twin Articulated Umbilical Spine & Corrugated Drain Hose Assembly
OEM articulated plastic caterpillar carrier with integrated corrugated drain hose and wiring guide.
Approx. $110 - $160 USD
Part 4
oem replacement part
Isolated Match
510727 Sump Rotor Silicone O-Ring Seal
Factory-specified silicone O-ring seal for the DishDrawer SmartDrive rotor sump well; mandatory replacement during rotor service to prevent sump leaks into the base pan.
$3.95 NZD / ~$3.00 USD
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified dishwashers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BLDCCarbon SteelEPDMPolypropyleneSiliconeStainless SteelStainless-Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not operate the DishDrawer dishwasher unless the motor rotor assembly, perforated stainless steel filter plate, cylindrical drain filter, and spray arm are all properly seated and locked in place, as unshielded debris can damage internal pump hydraulics.
  • Do not pinch opposing sides of the cylindrical drain filter mesh simultaneously during removal or cleaning, as this can fracture the plastic support ring.

Root Failure Mechanism: SmartDrive BLDC Motor Rotor Jam / Impeller Debris BindingClick to spotlight part ↑

01 // Trigger ConditionHard food debris (fruit seeds, pits, toothpicks, bone chips) or broken glass shards bypass the perforated sump filter plate or unseated cylindrical drain filter in a system without an internal hard food macerator.
02 // Degradation PhysicsForeign particles lodge in the pump chamber or abrade the permanent-magnet rotor assembly (PN 524922P / 524285P); because wash and drain impellers share a single reversible hub, a jammed rotor halts both wash circulation and drain pumping.
03 // Lockout / ImpactCycle aborts with standing water left in the wash tub and F2 / E2 error code displayed.

Root Failure Mechanism: Articulated Umbilical Drain Hose Cyclic Flexure Perforation or KinkingClick to spotlight part ↑

01 // Trigger ConditionRepeated daily drawer extension and retraction cycles bending the corrugated polypropylene drain hose inside the caterpillar carrier track, or insufficient rear cabinet clearance (<1.44 in) pinching the track.
02 // Degradation PhysicsHose kinking restricts wastewater flow when the drawer is pushed shut; over long-term cycling (5-10 years) combined with hot wastewater thermal aging, polymer fatigue creates microscopic stress fractures and pinhole leaks in the corrugated drain hose.
03 // Lockout / ImpactIntermittent water pooling inside the wash tub or slow leakage into the bottom drip pan that trips the F1 flood fault.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Warm, humid air venting from the concealed lower toe-kick / kickstrip area during and after the wash cycle.: The DD24DV2T9 uses a 12V DC centrifugal blower to actively extract moist vapor from the wash chamber and exhaust it through a concealed lower kickstrip vent during the drying phase. (True fault when: Indicates a fault only if liquid water pools on the floor, steam escapes around the upper drawer perimeter due to a torn lid gasket, or the F1 flood switch trips.)
False-Alarm Check — Brief mechanical whirring sound and pause after closing a drawer before cycle start, or before the drawer can be pulled open at cycle end.: Dual electric lid actuator motors vertically lower the rigid perimeter sealing lid onto the polymer tub rim after drawer closure and lift it clear when the cycle finishes or pauses. (True fault when: Indicates an obstruction or actuator failure if accompanied by grinding gear noise, inability to open/close the drawer, or error codes F52 / U3.)

Other Fisher & Paykel DD24DV2T9 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...