EXPLICIT FAULT CODE MODEL: AWF25

Arctic Air AWF25: P1

Observed Condition: Room Probe Failure (cabinet air temperature sensor open/shorted or loose harness)

Immediate Non-Invasive Triage: Inspect sensor wiring at controller; measure NTC probe resistance; compressor reverts to timed backup cycle.

Platform Cross-Reference: Alarm codes (P1, P2, P3, HA, LA) and solid-state controller reset logic (rst) apply across Arctic Air's digital reach-in platform.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
family OEM 65005 Digital Temperature Controller
Must match R290 spark-free agency listing and 45°F/54°F parameter map. Verify by serial/batch.
OEM ~$110–$165 / Generic ~$65–$95
Part 2
oem replacement part
family OEM 66110 Temperature Sensors (P1/P2)
Verify NTC vs. PTC resistance curve before substitution. Verify by serial/batch.
OEM ~$25–$45 / Generic ~$10–$20
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified commercial economy reach in freezer nsf 7 replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Servicing of the R290 hydrocarbon sealed system must be performed by factory-authorized personnel using like spark-free OEM components to prevent ignition risk.
  • Never use sharp/mechanical tools to chip ice off coils (puncture risk with flammable R290).

Root Mechanism: Temperature Probe Drift or Open Sensor Circuit (P1/P2 Alarms)

Trigger: Continuous operation, thermal cycling, or environmental exposure.

Physics / Degradation: Moisture ingress at probe crimp, cold-cycle wire fatigue, or internal sensor degradation leads to inaccurate resistance readings (drift) or an open circuit.

System Lockout / Impact: Controller logs P1 (room) or P2 (evaporator) alarm, leading to erratic compressor cycling, inefficient operation, or timed-only defrost (P2) causing evaporator coil ice-up and warming cabinet.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Evaporator fan stays off briefly after defrost ends.: The controller is programmed to hold the evaporator fan off until the evaporator coil temperature drops below 54°F (12.2°C) to prevent blowing warm air into the cabinet immediately after the defrost cycle. (True fault when: If the fan does not resume operation after the compressor has run for several minutes and the coil is visibly cold, then a fan motor or control fault may be present.)
False-Alarm Check — Compressor turns off and a defrost symbol illuminates on the LED display for a period.: This is a normal, scheduled 6-hour electric defrost cycle, which terminates at 45°F (7.2°C) coil temperature or after 20 minutes maximum. The cabinet will recover to its setpoint afterward. (True fault when: If the defrost cycle runs excessively long, fails to terminate, or the cabinet temperature does not recover to the setpoint after defrost, it may indicate a fault with the defrost heater, sensor, or controller.)

Other Arctic Air AWF25 Fault Signals