Observed Condition: Evaporator Probe Failure (evaporator coil temperature sensor fault)
Immediate Non-Invasive Triage: Defrost termination falls back strictly to 20-minute timed end instead of 45°F coil temp; test/replace evap probe.
Platform Cross-Reference: Alarm codes (P1, P2, P3, HA, LA) and solid-state controller reset logic (rst) apply across Arctic Air's digital reach-in platform.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
family OEM 65005 | Digital Temperature Controller Must match R290 spark-free agency listing and 45°F/54°F parameter map. Verify by serial/batch. |
OEM ~$110–$165 / Generic ~$65–$95 | |
| Part 2 oem replacement part |
family OEM 66110 | Temperature Sensors (P1/P2) Verify NTC vs. PTC resistance curve before substitution. Verify by serial/batch. |
OEM ~$25–$45 / Generic ~$10–$20 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified commercial economy reach in freezer nsf 7 replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Continuous operation, thermal cycling, or environmental exposure.
Physics / Degradation: Moisture ingress at probe crimp, cold-cycle wire fatigue, or internal sensor degradation leads to inaccurate resistance readings (drift) or an open circuit.
System Lockout / Impact: Controller logs P1 (room) or P2 (evaporator) alarm, leading to erratic compressor cycling, inefficient operation, or timed-only defrost (P2) causing evaporator coil ice-up and warming cabinet.