Observed Condition: Cans/bottles slushy or frozen (below 32°F).
Immediate Non-Invasive Triage: Reduce mechanical knob to 3–4; ensure cans do not block interior airflow vents. If compressor never cycles off at setting 1, mechanical thermostat contacts may be welded shut.
Platform Cross-Reference: Da Pan Electric Appliance SC-330FB chassis is shared with VEVOR SC-330FB; BODEGA warranty policy applies brand-wide (1-year standard, 2-year direct bodegacooler.com with registration).
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 universal aftermarket part |
Commercial beverage… | Mechanical Rotary Thermostat Match cut-in/cut-out temperature curve, capillary bulb length, and electrical ratings. |
$12–$28 | |
| Part 2 oem replacement part |
EC-4P-4-26-A | Evaporator Fan Motor Must match voltage, frequency, motor type (EC), physical dimensions, and mounting. |
$25–$55 (est. generic/OEM) | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified freestanding glass door beverage coolers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Repeated switching of inductive compressor load (2.0A) or electrical transients.
Physics / Degradation: Electrical arcing causes contact pitting or welding, or the capillary sensing bulb loses gas charge over time.
System Lockout / Impact: Thermostat fails to accurately control temperature, resulting in either continuous freezing (below 32°F) or a no-cool condition.
Trigger: Continuous duty operation, exposure to moisture (evaporator fan), or dust/heat (condenser fan).
Physics / Degradation: Sleeve bearings dry out, accumulate debris, or corrode, leading to increased friction and eventual motor seizure.
System Lockout / Impact: Evaporator fan failure causes icing and poor internal air circulation; condenser fan failure causes compressor overheating and reduced cooling capacity. Both lead to insufficient cooling.