HARDWARE SYMPTOM MODEL: SC-330FB-BK

BODEGA SC-330FB-BK: Over-Freezing Beverages

Observed Condition: Cans/bottles slushy or frozen (below 32°F).

Immediate Non-Invasive Triage: Reduce mechanical knob to 3–4; ensure cans do not block interior airflow vents. If compressor never cycles off at setting 1, mechanical thermostat contacts may be welded shut.

Platform Cross-Reference: Da Pan Electric Appliance SC-330FB chassis is shared with VEVOR SC-330FB; BODEGA warranty policy applies brand-wide (1-year standard, 2-year direct bodegacooler.com with registration).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
Commercial beverage… Mechanical Rotary Thermostat
Match cut-in/cut-out temperature curve, capillary bulb length, and electrical ratings.
$12–$28
Part 2
oem replacement part
EC-4P-4-26-A Evaporator Fan Motor
Must match voltage, frequency, motor type (EC), physical dimensions, and mounting.
$25–$55 (est. generic/OEM)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified freestanding glass door beverage coolers replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not puncture refrigerant lines or perform unauthorized electrical modifications.
  • Keep cabinet upright and unplugged for more than 24 hours before powering on so compressor lubricant settles back into the sump.

Root Mechanism: Mechanical Thermostat Drift or Contact Welding

Trigger: Repeated switching of inductive compressor load (2.0A) or electrical transients.

Physics / Degradation: Electrical arcing causes contact pitting or welding, or the capillary sensing bulb loses gas charge over time.

System Lockout / Impact: Thermostat fails to accurately control temperature, resulting in either continuous freezing (below 32°F) or a no-cool condition.

Root Mechanism: Evaporator or Condenser Fan Motor Bearing Seizure

Trigger: Continuous duty operation, exposure to moisture (evaporator fan), or dust/heat (condenser fan).

Physics / Degradation: Sleeve bearings dry out, accumulate debris, or corrode, leading to increased friction and eventual motor seizure.

System Lockout / Impact: Evaporator fan failure causes icing and poor internal air circulation; condenser fan failure causes compressor overheating and reduced cooling capacity. Both lead to insufficient cooling.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Lack of Built-In Temperature Readout: SC-330FB-BK uses a 7-level mechanical rotary knob for temperature control and does not include a digital temperature display as a design characteristic. (True fault when: This is a design characteristic, not a fault. If the internal temperature is outside the 32°F–50°F range despite proper thermostat setting, it indicates a cooling system fault (see diag_01, diag_02).)
False-Alarm Check — Shallow Shelf Retention Lip Height: The front lip on the painted steel wire shelves is shallow by design. This is an ergonomic characteristic of the shelves. (True fault when: This is a design characteristic, not a fault. Ensure the cabinet is level or tilted very slightly rearward (1–2 mm) so bottles do not roll forward when opening the door.)

Other BODEGA SC-330FB-BK Fault Signals