Observed Condition: Drinks above 50°F, compressor running continuously.
Immediate Non-Invasive Triage: Verify thermostat dial is set to 4–7, check rear/side ventilation clearance, inspect bottom condenser for dust, confirm both evaporator (EC-4P-4-26-A) and condenser fans spin.
Platform Cross-Reference: Da Pan Electric Appliance SC-330FB chassis is shared with VEVOR SC-330FB; BODEGA warranty policy applies brand-wide (1-year standard, 2-year direct bodegacooler.com with registration).
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
EC-4P-4-26-A | Evaporator Fan Motor Must match voltage, frequency, motor type (EC), physical dimensions, and mounting. |
$25–$55 (est. generic/OEM) | |
| Part 2 oem replacement part |
115V 60Hz R600a LBP/MBP… | Hermetic R600a Compressor Must match refrigerant type, voltage, frequency, cooling capacity (BTU/hr), and mounting. Installation requires EPA certification for R600a. |
$85–$160 (part only, excl. EPA labor) | |
| Part 3 universal aftermarket part |
UL-recognized CBB65/CBB60… | Compressor Run/Start Capacitor Always match exact uF tolerance (+/-5%) and voltage printed on original capacitor for safe operation. |
$8–$18 | |
| Part 4 universal aftermarket part |
Commercial beverage… | Mechanical Rotary Thermostat Match cut-in/cut-out temperature curve, capillary bulb length, and electrical ratings. |
$12–$28 | |
| Part 5 oem replacement part |
Custom-cut commercial… | Magnetic Door Gasket Requires exact profile match for proper seal and retention. Dimensions (~22 in. x 70 in.) are critical. |
$45–$95 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified freestanding glass door beverage coolers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Unit placed in dusty environment or with insufficient ventilation clearance.
Physics / Degradation: Floor-level intake draws lint and debris, clogging condenser fins. This restricts heat rejection, causing condensing pressure and compressor winding temperature to spike.
System Lockout / Impact: Compressor thermal overload protector trips, leading to intermittent or complete loss of cooling, and reduced product lifespan.
Trigger: Repeated switching of inductive compressor load (2.0A) or electrical transients.
Physics / Degradation: Electrical arcing causes contact pitting or welding, or the capillary sensing bulb loses gas charge over time.
System Lockout / Impact: Thermostat fails to accurately control temperature, resulting in either continuous freezing (below 32°F) or a no-cool condition.