Error Code Model: CM-54RS

CHUMART CM-54RS: P1 or P2 (flashing on display)

What this means: P1: Room NTC Probe fault (open/short); P2: Evaporator NTC Probe fault (open/short)

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Temporary 3–6°F rise in cabinet temperature and compressor pause — This is a normal part of the automatic defrost cycle, where the evaporator coil is briefly warmed to melt accumulated frost.

Inspect probe connector at Dixell terminal block. P1 forces timed compressor cycling.

2

Verified Replacement Parts

#1 Most Likely Fix Generic: $10–$22

NTC Temperature Probe

Dixell-compatible 10kΩ… Copy Part #

Must match NTC thermistor resistance curve (10kΩ @ 25°C) and physical dimensions/lead length.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in commercial reach in refrigerator replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • The R-290 sealed vapor-compression loop contains A3 flammable hydrocarbon refrigerant. Any breach requires an EPA Section 608-certified technician trained in flammable R-290 procedures.
  • The foamed-in-place insulated cabinet is permanently bonded and non-serviceable; concealed structural damage or foam saturation cannot be field-repaired.
Dixell NTC Probe Drift or Open Circuit (P1/P2)

What triggers it: Moisture ingress, wire fatigue, or sensor degradation over time.

What wears out inside: NTC thermistor resistance drifts out of calibration or circuit becomes open/shorted.

Symptom on machine: Controller receives incorrect temperature readings, leading to `P1` (room probe) or `P2` (evap probe) fault codes, forcing timed compressor cycling or timed defrost, and potentially poor temperature control.

Cross-Compatible Platforms: CHUMART's reach-in maintenance schedule (daily temp log, weekly gasket/drain check, 30–90 day condenser cleaning)

Other CHUMART CM-54RS Problems (4)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...