Symptom Guide Model: IE-36R

ICECASA IE-36R: Elevated Cabinet Temperature (>41°F)

What this means: Unit runs continuously or holds above 41°F.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Temporary LCD temperature display increase every 4 hours. — This is a normal consequence of the automatic electric defrost cycle, which temporarily warms the evaporator coil to melt frost.

Check power and setpoint; clean condenser coil; verify YZF6-13 condenser fan spins when NUT45NR compressor is running; check door seal.

Target: 41°F
2

Verified Replacement Parts

#1 Most Likely Fix OEM: $68.00 / Generic: ~$20–$32

Condenser Fan Motor

YZF6-13 Copy Part #

Official OEM listing (eBay #167781159498) explicitly lists ICE-36R and WK-48R fitment.

Option #2 • Secondary / Related Part Check Live Stock

Magnetic Snap-In Door Gasket

Flexible Extruded PVC… Copy Part #

Standard commercial reach-in magnetic gasket construction. Tool-free dart channel mounting.

Option #3 • Secondary / Related Part OEM: ~$165–$235 / Generic: ~$135–$185

Replacement R290 Compressor

NUT45NR Copy Part #

Official OEM listing explicitly lists fitment for ICE-36R. Requires hydrocarbon-rated service procedures.

Option #4 • Secondary / Related Part OEM: ~$48–$65 / Generic: ~$25–$40

Evaporator Fan Motor

NEC4810 Copy Part #

Official OEM listing (eBay #167781157538) explicitly lists ICE-36R fitment.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in commercial reach in refrigeration replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Servicing the sealed R290 hydrocarbon vapor-compression loop requires a licensed commercial refrigeration technician trained in Class A3 flammable R290 hydrocarbon handling.
Condenser Fin Fouling leading to High Head Pressure & Compressor Overload Trip

What triggers it: Operation in commercial kitchen environment with airborne grease and dust.

What wears out inside: Accumulation of grease and dust on condenser fins restricts airflow and heat transfer, leading to elevated condensing pressure and discharge temperature.

Symptom on machine: Compressor trips on thermal overload, leading to loss of cooling and cabinet warming above 41°F.

Evaporator Coil Icing from Gasket Leak or Door Left Ajar

What triggers it: Debris or tear in magnetic gasket, or shelf obstruction preventing full door closure.

What wears out inside: Warm, humid kitchen air enters the cabinet, leading to excessive frost accumulation on the evaporator coil, exceeding the 4-hour defrost capacity.

Symptom on machine: Blocked evaporator airflow results in reduced cooling capacity and elevated cabinet temperature.

Cross-Compatible Platforms: Shares CAREL / HK-304 digital controller architecture, 2-wire NTC sensor harness, NEC4810 evaporator fan motor, 4-hour automatic defrost cycle, and 2-year parts/labor + 6-year compressor warranty with the 54-inch ICE-49R (B0DTB69G25).