ICECASA IE-36R: Elevated Cabinet Temperature (>41°F)
What this means: Unit runs continuously or holds above 41°F.
60-Second Verification Check
Check power and setpoint; clean condenser coil; verify YZF6-13 condenser fan spins when NUT45NR compressor is running; check door seal.
Verified Replacement Parts
Condenser Fan Motor
Official OEM listing (eBay #167781159498) explicitly lists ICE-36R and WK-48R fitment.
Magnetic Snap-In Door Gasket
Standard commercial reach-in magnetic gasket construction. Tool-free dart channel mounting.
Replacement R290 Compressor
Official OEM listing explicitly lists fitment for ICE-36R. Requires hydrocarbon-rated service procedures.
Evaporator Fan Motor
Official OEM listing (eBay #167781157538) explicitly lists ICE-36R fitment.
Why This Happens & Safety Warnings
- Servicing the sealed R290 hydrocarbon vapor-compression loop requires a licensed commercial refrigeration technician trained in Class A3 flammable R290 hydrocarbon handling.
What triggers it: Operation in commercial kitchen environment with airborne grease and dust.
What wears out inside: Accumulation of grease and dust on condenser fins restricts airflow and heat transfer, leading to elevated condensing pressure and discharge temperature.
Symptom on machine: Compressor trips on thermal overload, leading to loss of cooling and cabinet warming above 41°F.
What triggers it: Debris or tear in magnetic gasket, or shelf obstruction preventing full door closure.
What wears out inside: Warm, humid kitchen air enters the cabinet, leading to excessive frost accumulation on the evaporator coil, exceeding the 4-hour defrost capacity.
Symptom on machine: Blocked evaporator airflow results in reduced cooling capacity and elevated cabinet temperature.
Cross-Compatible Platforms: Shares CAREL / HK-304 digital controller architecture, 2-wire NTC sensor harness, NEC4810 evaporator fan motor, 4-hour automatic defrost cycle, and 2-year parts/labor + 6-year compressor warranty with the 54-inch ICE-49R (B0DTB69G25).