HARDWARE SYMPTOM MODEL: IE-36R TIER 3 BENCH / MULTIMETER

ICECASA IE-36R: Water Pooling Under Cabinet

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Water on floor beneath refrigerator.

02 // Non-Invasive Meter / Bench Verification

Verify casters sit level with brakes locked; flush condensate drain line and inspect lower pan.

Platform / OEM Cross-Reference: Shares CAREL / HK-304 digital controller architecture, 2-wire NTC sensor harness, NEC4810 evaporator fan motor, 4-hour automatic defrost cycle, and 2-year parts/labor + 6-year compressor warranty with the 54-inch ICE-49R (B0DTB69G25).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
NUT45NR Replacement R290 Compressor
Official OEM listing explicitly lists fitment for ICE-36R. Requires hydrocarbon-rated service procedures.
OEM: ~$165–$235 / Generic: ~$135–$185
Part 2
oem replacement part
Isolated Match
167889870356 Digital Temperature Controller
Official OEM listing (eBay #167889870356) explicitly lists ICE-36R fitment.
OEM: ~$45–$75 / Generic: ~$35–$60
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial reach in refrigeration replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:Carbon SteelCopperNTCR290Stainless SteelStainless-Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Servicing the sealed R290 hydrocarbon vapor-compression loop requires a licensed commercial refrigeration technician trained in Class A3 flammable R290 hydrocarbon handling.

Root Failure Mechanism: Condensate Drain Tube Clog leading to Floor Water PoolingClick to spotlight part ↑

01 // Trigger ConditionAccumulation of slime, food particles, or debris in the gravity drain tube.
02 // Degradation PhysicsBlocked drain tube prevents defrost meltwater from reaching the self-evaporating pan.
03 // Lockout / ImpactDefrost water overflows inside the cabinet or spills onto the kitchen floor, creating a slip hazard and potential damage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Temporary LCD temperature display increase every 4 hours.: This is a normal consequence of the automatic electric defrost cycle, which temporarily warms the evaporator coil to melt frost. (True fault when: Failure to pull back down to 33°F–41°F within 45–60 minutes after defrost ends.)
False-Alarm Check — Internal evaporator airflow pauses when door is opened.: The evaporator fan turns off when the door opens to prevent warm kitchen air from being drawn across the cold coil, reducing frost buildup and energy loss. (True fault when: Evaporator fan (NEC4810) does not run when both doors are closed.)