Kratos 67K-007: Clicking after brief power outage
What this means: Compressor start relay attempting to engage the compressor motor, but failing due to high head pressure.
60-Second Verification Check
Unplug unit and wait ≥10 minutes for high/low-side pressures to equalize before restarting.
Verified Replacement Parts
Hermetic Compressor (1/3 HP, R-290a)
OEM part ensures exact fit, performance, and R-290a compatibility. Generic must match all specifications precisely for safety and function.
Why This Happens & Safety Warnings
- Repairs beyond user cleaning must be performed by a qualified technician.
- Do not modify wiring or install unauthorized electrical parts.
What triggers it: Re-energizing the unit within 10 minutes of a power outage or being unplugged.
What wears out inside: Attempting to start the compressor before high and low-side pressures have equalized. This creates a locked-rotor condition, causing excessive current draw and stress on the motor windings, start relay, and capacitor.
Symptom on machine: Compressor motor burnout, start component failure, unit failing to cool, requiring expensive sealed-system repair.
Cross-Compatible Platforms: Shares 23 cu. ft. chassis, 67K-P60 compressor, Pos 25 condenser fan, and 67K Reach-In Manual rules (6"/12" clearances, <80°F/<65% RH optimal, ≤20A breaker, 10-min restart delay, commercial-use-only warranty) with solid-door sibling 67K-001.