Kratos 67K-007: Ice visible on coil, rising cabinet temp, weak airflow
What this means: Evaporator coil is accumulating ice, blocking airflow and reducing cooling capacity.
60-Second Verification Check
Verify automatic defrost cycle is active and door gasket seals tightly. Check for prolonged door-open events.
Verified Replacement Parts
Magnetic Door Gasket
OEM part ensures exact fit and magnetic seal. Generic must match dimensions and material properties.
Why This Happens & Safety Warnings
- Repairs beyond user cleaning must be performed by a qualified technician.
- Do not modify wiring or install unauthorized electrical parts.
What triggers it: Malfunctioning automatic defrost system, prolonged door-open events, or severe air infiltration due to a faulty door gasket.
What wears out inside: Ice builds up on the evaporator coil, blocking airflow from the evaporator fan and reducing the coil's ability to absorb heat from the cabinet.
Symptom on machine: Cabinet fails to hold set temperature (33°F–41°F), spoiled product, increased energy consumption.
Cross-Compatible Platforms: Shares 23 cu. ft. chassis, 67K-P60 compressor, Pos 25 condenser fan, and 67K Reach-In Manual rules (6"/12" clearances, <80°F/<65% RH optimal, ≤20A breaker, 10-min restart delay, commercial-use-only warranty) with solid-door sibling 67K-001.