UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: 2679182

Kenmore 2679182: Extended Dry Times

Observed Condition: Load takes multiple cycles to dry.

Immediate Non-Invasive Triage: Check exterior vent hood airflow; clean ducting and lint screen before replacing parts.

Platform Cross-Reference: Follows Kenmore 79xxx residential vented gas dryer architecture.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Exact-temperature rated… Thermal Fuse / TCO Kit
Critical safety component; must be an exact OEM-specified replacement with the correct temperature rating. Never bypass.
~$15–$35 OEM
Part 2
oem replacement part
Dual-coil (2-terminal &… Gas Valve Solenoid Coil Kit
Must match voltage and terminal configuration for proper gas valve operation and safety.
~$25–$45 OEM / ~$12–$20 Generic
Part 3
oem replacement part
120V Silicon… Hot-Surface Igniter (HSI)
Must match voltage, wattage, and physical dimensions for safe and effective ignition.
~$30–$60 OEM / ~$15–$25 Generic
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified residential freestanding vented gas clothes dryer replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Root Mechanism: Exhaust Restriction Leading to Thermal Fuse Open

Trigger: Failure to clean lint filter or exhaust ducting.

Physics / Degradation: Lint blockage restricts airflow, causing exhaust temperature to spike.

System Lockout / Impact: Single-use thermal fuse opens, resulting in no heat or complete dryer shutdown.

Root Mechanism: Gas Valve Solenoid Coil Thermal Drift/Failure

Trigger: Repeated thermal cycling and aging of solenoid coils.

Physics / Degradation: Aged solenoid coils develop increased resistance or open circuits when warm.

System Lockout / Impact: Burner lights initially but fails to relight mid-cycle, leading to no heat or extended dry times.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Soft click and ignition whoosh intermittently: This is expected operation as the cycling thermostat regulates drum temperature by turning the gas burner on and off. (True fault when: If the burner fails to ignite or stays off for extended periods when heat is called for, it may indicate a fault.)

Other Kenmore 2679182 Fault Signals