FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: 2679182 TIER 1–2 BENCH DIY

Kenmore 2679182: No Heat / Intermittent Heat

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Drum tumbles with cold air; burner fails to relight.

02 // Non-Invasive Meter / Bench Verification

Check igniter glow; test continuity of thermal fuse and resistance of gas valve coils.

Platform / OEM Cross-Reference: Follows Kenmore 79xxx residential vented gas dryer architecture.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Exact-temperature rated… Thermal Fuse / TCO Kit
Critical safety component; must be an exact OEM-specified replacement with the correct temperature rating. Never bypass.
~$15–$35 OEM
Part 2
oem replacement part
Isolated Match
Dual-coil (2-terminal &… Gas Valve Solenoid Coil Kit
Must match voltage and terminal configuration for proper gas valve operation and safety.
~$25–$45 OEM / ~$12–$20 Generic
Part 3
oem replacement part
Isolated Match
120V Silicon… Hot-Surface Igniter (HSI)
Must match voltage, wattage, and physical dimensions for safe and effective ignition.
~$30–$60 OEM / ~$15–$25 Generic
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified residential freestanding vented gas clothes dryer replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BRASSEPDMNTC

Failure Physics & Causal Isolation

Root Failure Mechanism: Exhaust Restriction Leading to Thermal Fuse OpenClick to spotlight part ↑

01 // Trigger ConditionFailure to clean lint filter or exhaust ducting.
02 // Degradation PhysicsLint blockage restricts airflow, causing exhaust temperature to spike.
03 // Lockout / ImpactSingle-use thermal fuse opens, resulting in no heat or complete dryer shutdown.

Root Failure Mechanism: Gas Valve Solenoid Coil Thermal Drift/FailureClick to spotlight part ↑

01 // Trigger ConditionRepeated thermal cycling and aging of solenoid coils.
02 // Degradation PhysicsAged solenoid coils develop increased resistance or open circuits when warm.
03 // Lockout / ImpactBurner lights initially but fails to relight mid-cycle, leading to no heat or extended dry times.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Soft click and ignition whoosh intermittently: This is expected operation as the cycling thermostat regulates drum temperature by turning the gas burner on and off. (True fault when: If the burner fails to ignite or stays off for extended periods when heat is called for, it may indicate a fault.)

Other Kenmore 2679182 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...