UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: MLC27N3AWW

Midea MLC27N3AWW: E10

Observed Condition: Water Fill Timeout

Immediate Non-Invasive Triage: Verify hot/cold faucets are fully open and supply pressure is 20–100 psi; inspect inlet mesh screens before testing valve coils.

Platform Cross-Reference: Shares Midea's compact 24-in. 2.7 cu. ft. (161 lb) ventless condensing platform and E10/E12/E21/E30 diagnostic fault architecture.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
17438100000415 Water Inlet Valve (Pos 30)
OEM part ensures exact fit, electrical compatibility, and pressure rating. Generic match requires careful verification of specifications.
~$32.95 OEM
Part 2
oem replacement part
17438000000464 Water Inlet Valve (Pos 29)
OEM part ensures exact fit, electrical compatibility, and pressure rating. Generic match requires careful verification of specifications.
~$14.95 OEM
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified all in one ventless washer dryers replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not attempt unauthorized internal repairs.
  • Damaged power cords must be replaced with an OEM cord via manufacturer/service center to preserve safety and coverage.

Root Mechanism: Water Fill Fault / Valve Scale Fouling (E10)

Trigger: Water fill cycle initiation

Physics / Degradation: Hard water sediment or low supply pressure (<20 psi) restricts water flow through inlet valve screens or valve solenoids.

System Lockout / Impact: Insufficient water fill, cycle timeout, and triggering of E10 error code.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — ~3.5–4+ hours for full wash-and-dry cycle; garments feel warm/damp on removal: 120V ventless condensing drying is inherently slower and less efficient than vented drying. Moisture is condensed using cold water, requiring longer cycles. Garments may feel slightly steam-damp until shaken out for 1–2 min due to residual steam. The 'Overnight Dry' mode acknowledges this characteristic. (True fault when: Sudden multi-hour increases in cycle time beyond typical 3.5-4 hours, or garments remaining heavily wet, may indicate lint buildup in the drying tunnel/base (Pos 51/51.5) or a tripped thermostat (Pos 51.3).)

Other Midea MLC27N3AWW Fault Signals