Observed Condition: Water Fill Timeout
Immediate Non-Invasive Triage: Verify hot/cold faucets are fully open and supply pressure is 20–100 psi; inspect inlet mesh screens before testing valve coils.
Platform Cross-Reference: Shares Midea's compact 24-in. 2.7 cu. ft. (161 lb) ventless condensing platform and E10/E12/E21/E30 diagnostic fault architecture.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
17438100000415 | Water Inlet Valve (Pos 30) OEM part ensures exact fit, electrical compatibility, and pressure rating. Generic match requires careful verification of specifications. |
~$32.95 OEM | |
| Part 2 oem replacement part |
17438000000464 | Water Inlet Valve (Pos 29) OEM part ensures exact fit, electrical compatibility, and pressure rating. Generic match requires careful verification of specifications. |
~$14.95 OEM | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified all in one ventless washer dryers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Water fill cycle initiation
Physics / Degradation: Hard water sediment or low supply pressure (<20 psi) restricts water flow through inlet valve screens or valve solenoids.
System Lockout / Impact: Insufficient water fill, cycle timeout, and triggering of E10 error code.