Observed Condition: Water Overflow Detection
Immediate Non-Invasive Triage: Verify HE detergent dosing; check if water enters when powered off (indicates mechanical inlet valve weep).
Platform Cross-Reference: Shares Midea's compact 24-in. 2.7 cu. ft. (161 lb) ventless condensing platform and E10/E12/E21/E30 diagnostic fault architecture.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
17438100001348 | Water Level Sensor (Pos 7) OEM part is critical for accurate water level sensing and fault detection. Generic swaps are not recommended due to specific calibration. |
~$9.95 OEM | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified all in one ventless washer dryers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Water fill cycle or idle state
Physics / Degradation: Debris in the pressure tube to the water level sensor, or a leaking/stuck-open inlet solenoid valve.
System Lockout / Impact: False high-water detection, actual overfill condition, or continuous water entry when off, triggering E12 shutdown.