FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: 76328010xx TIER 4 LICENSED / SEALED

LUTEC 76328010xx: Reduced Motion Detection Range

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Sensor only triggers at short distance (less than 20 ft).

02 // Non-Invasive Meter / Bench Verification

Set 'DISTANCE' to 'H', clean Fresnel lens, verify mounting height and lateral (across-field) walk path.

Platform / OEM Cross-Reference: 14-second PIR startup warm-up and 10-second wall-switch override reset from LUTEC 7632812xxx sibling manual.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
not applicable
Isolated Match
Integrated LED Heads … Integrated LED Heads / Internal Driver / PIR Pod
Proprietary mechanical & thermal form factor; not sold as spare parts.
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified outdoor security floodlights replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCast AluminumCast-AluminumCopperEPDMSiliconeTRIAC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not open the light heads as the integrated LED modules are not user-replaceable and are factory-sealed for IP65 weatherproofing and thermal coupling.
  • Do not use abrasive cleaners, chemical solvents, or sharp objects on lenses or housing.

Root Failure Mechanism: UV Crazing / Clouding of PIR Fresnel LensClick to spotlight part ↑

01 // Trigger ConditionMulti-year direct southern/western UV exposure or harsh chemical cleaning.
02 // Degradation PhysicsUV radiation causes degradation (crazing, hazing, yellowing) of the HDPE Fresnel lens material, reducing its infrared transmission.
03 // Lockout / ImpactShortened motion detection distance and reduced PIR sensitivity.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Light does not respond to motion for ~14 seconds after power-on.: This is a normal PIR sensor warm-up and stabilization period after initial power application. (True fault when: If the light never responds to motion after the warm-up period, it may indicate a fault.)
False-Alarm Check — Light stays on for only ~5 seconds even during daylight.: The 'TEST' mode is designed for quick aiming and verification, overriding the photocell and using a fixed short duration. (True fault when: If the light stays on for less than 5 seconds in 'TEST' mode, or if it behaves this way when 'TIME' is set to 1, 3, or 10 MIN.)

Other LUTEC 76328010xx Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...