LUTEC 76328010xx: Stuck ON / Constant Illumination
What this means: Light stays on continuously at 100% brightness.
60-Second Verification Check
Flip wall switch OFF for greater than 10 seconds, then ON to exit 6-hr Manual Override; lower 'DISTANCE' to 'L' or 'M'; check for HVAC exhaust or moving foliage.
Verified Replacement Parts
Integrated LED Heads / Internal Driver / PIR Pod
Proprietary mechanical & thermal form factor; not sold as spare parts.
Why This Happens & Safety Warnings
- Do not open the light heads as the integrated LED modules are not user-replaceable and are factory-sealed for IP65 weatherproofing and thermal coupling.
- Do not use abrasive cleaners, chemical solvents, or sharp objects on lenses or housing.
What triggers it: High 'DISTANCE' setting, HVAC exhaust plumes, spiderwebs on Fresnel lens, or accidental wall-switch double-toggle (Manual Override).
What wears out inside: PIR sensor misinterprets non-human heat/motion, photocell is blinded, or control logic is latched into Manual Override.
Symptom on machine: Continuous 100% illumination, premature thermal wear on LEDs/driver, or wasted energy.
Cross-Compatible Platforms: 14-second PIR startup warm-up and 10-second wall-switch override reset from LUTEC 7632812xxx sibling manual.