DALY 200A-8-24S: Balancing stops while a cell is high; pack stays imbalanced
What this means: Firmware logic: Cell Volt Hi Level 1 alarm (0.1V below HVD) disables active balancing until cleared.
60-Second Verification Check
Check app alarm logs for Level 1 High Voltage alarm; lower charger absorption voltage slightly below Level 1 threshold so active balancer remains active during top-balance, and check for firmware updates.
Verified Replacement Parts
External 3" or 4.3" Touch LCD Display
Proprietary serial protocol; plugs into UART port for local non-Bluetooth monitoring.
Why This Happens & Safety Warnings
- Manual explicitly warns that incorrect sampling cable wiring damages the BMS and poses a fire hazard, implying internal components are not user-serviceable and sensitive to external wiring errors. (``)
What triggers it: A cell voltage reaches the Level 1 High Voltage warning threshold (0.1V below High Voltage Disconnect).
What wears out inside: BMS firmware suspends the 1A active balancing operation.
Symptom on machine: The battery pack remains top-imbalanced, potentially reducing usable capacity or triggering HVD prematurely.
Cross-Compatible Platforms: Cell voltage sampling range 1.5V–4.9V.