DALY 200A-8-24S: No output voltage at P-, no Bluetooth broadcast, LED off
What this means: BMS is in factory shipping sleep mode or has entered 1-hour inactivity sleep timer.
60-Second Verification Check
Verify B+/B- and sampling cable order; apply charger delivering ≥2A at ≥2V above pack voltage to wake BMS. Set 'Sleep Waiting Time' to '65535' in app to prevent unwanted sleep.
Verified Replacement Parts
External 3" or 4.3" Touch LCD Display
Proprietary serial protocol; plugs into UART port for local non-Bluetooth monitoring.
Why This Happens & Safety Warnings
- Manual explicitly warns that incorrect sampling cable wiring damages the BMS and poses a fire hazard, implying internal components are not user-serviceable and sensitive to external wiring errors. (``)
What triggers it: BMS enters default 1-hour inactivity sleep timer or factory shipping sleep mode, combined with low-voltage disconnect.
What wears out inside: MOSFETs open (disconnecting pack), Bluetooth shuts down, and LED turns off.
Symptom on machine: User perceives the BMS as 'dead' or faulty, leading to system lockout until manually woken.
Cross-Compatible Platforms: Cell voltage sampling range 1.5V–4.9V.