IYILO IYILO-RA48: Charger stops initiating sessions after extended offline use
What this means: Internal log memory saturation due to prolonged offline operation prevents new charging sessions.
60-Second Verification Check
Connect to 2.4 GHz Wi-Fi and execute OTA firmware update via IYILO App.
Verified Replacement Parts
Replacement J1772 Cable / Mainboard / Relays
Core internal assemblies are not field-swappable. Requires factory service to maintain safety certifications and warranty.
Why This Happens & Safety Warnings
- Unauthorized internal disassembly beyond the installer wiring compartment voids warranty.
- J1772 connector head is factory-assembled/sealed; field replacement of individual pins or the internal thermistor is not supported.
What triggers it: Prolonged use of Plug & Charge without Wi-Fi connectivity.
What wears out inside: Internal log buffer or non-volatile memory on the mainboard fills up, preventing further session logging.
Symptom on machine: EVSE halts charging sessions and becomes unresponsive until connected to Wi-Fi for an OTA firmware update to clear the memory.
Cross-Compatible Platforms: Shares chassis, manual, NEMA 4 rating, 25-ft cable, and 3-year warranty with IYILO-RA40 (40A-only sibling) and NACS/Pro Energy Meter variants.