FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: IYILO-RA48 TIER 4 LICENSED / SEALED

IYILO IYILO-RA48: Solid Green / Solid Blue / Solid Red indicators

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Multi-color LED array on the front panel indicates operational status (ready, charging, network, fault).

02 // Non-Invasive Meter / Bench Verification

Refer to manual for specific LED patterns. Red indicates fault condition requiring app/breaker inspection.

Platform / OEM Cross-Reference: Shares chassis, manual, NEMA 4 rating, 25-ft cable, and 3-year warranty with IYILO-RA40 (40A-only sibling) and NACS/Pro Energy Meter variants.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Replacement J1772 Cable … Replacement J1772 Cable / Mainboard / Relays
Core internal assemblies are not field-swappable. Requires factory service to maintain safety certifications and warranty.
Warranty / Quote
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified level 2 smart ev chargers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopperEPDMNTCSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Unauthorized internal disassembly beyond the installer wiring compartment voids warranty.
  • J1772 connector head is factory-assembled/sealed; field replacement of individual pins or the internal thermistor is not supported.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Audible relay click at session start/stop; slight cable/plug warmth at 40A–48A: Relay clicks are normal as the internal high-current switching relays engage and disengage. Slight warmth in the cable and plug is expected due to I^2R Joule heating during high-current continuous charging. (True fault when: Hot-to-touch plug, buzzing relay, or excessive cable heat (beyond slight warmth) indicates a potential fault requiring inspection.)

Other IYILO IYILO-RA48 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...