VEVOR HD24200-48: BMS cuts out instantly when turning on a 2000W–3000W inverter
What this means: High inrush current from large inverter input capacitors momentarily exceeds BMS overcurrent threshold.
60-Second Verification Check
Use a 25–50 Ω pre-charge resistor before closing the main DC breaker to limit inrush current.
Verified Replacement Parts
Complete Battery Module
Must match voltage, capacity, BMS current rating, and physical dimensions for system compatibility.
Why This Happens & Safety Warnings
- Do not pry or cut open the sealed plastic casing during the 12-month warranty window; contact VEVOR support first (implied by warranty policy and sealed design).
What triggers it: Connecting >2560W inverter or high-inrush load without pre-charge, or continuous load exceeding 100A.
What wears out inside: Instantaneous current spike or sustained current exceeds 100A BMS limit, triggering MOSFET protection.
Symptom on machine: Output disconnect, load shuts off. Repeated trips can potentially degrade BMS components over time.
Cross-Compatible Platforms: 12-month standard VEVOR warranty and mixed buyer/teardown feedback on shipping protection and RMA support apply at the VEVOR LiFePO4 brand-family level.