VEVOR HD24200-48: Sudden 0V–5V reading on multimeter; load shuts off
What this means: BMS has triggered a protection event (overcurrent, low-voltage, high-voltage, low-temp charge block) and disconnected the battery output.
60-Second Verification Check
Disconnect load; check if triggered by >100A overcurrent, <20V low-voltage, >29.2V high-voltage, or <0 °C low-temp charge block. Apply LiFePO4 charger with 0V wake-up to reset.
Verified Replacement Parts
Complete Battery Module
Must match voltage, capacity, BMS current rating, and physical dimensions for system compatibility.
Why This Happens & Safety Warnings
- Do not pry or cut open the sealed plastic casing during the 12-month warranty window; contact VEVOR support first (implied by warranty policy and sealed design).
What triggers it: Connecting >2560W inverter or high-inrush load without pre-charge, or continuous load exceeding 100A.
What wears out inside: Instantaneous current spike or sustained current exceeds 100A BMS limit, triggering MOSFET protection.
Symptom on machine: Output disconnect, load shuts off. Repeated trips can potentially degrade BMS components over time.
Cross-Compatible Platforms: 12-month standard VEVOR warranty and mixed buyer/teardown feedback on shipping protection and RMA support apply at the VEVOR LiFePO4 brand-family level.