Abovizo AB22: Complete Failure to Illuminate (Dead Fixture)
What this means: None of the three LED lamp heads illuminate in either Dusk-to-Dawn mode or Motion Sensor mode despite dark ambient conditions.
60-Second Verification Check
1. Verify that the wall toggle switch is ON and the upstream circuit breaker or GFCI has not tripped. 2. Switch the fixture to Dusk-to-Dawn mode and cover the photocell window completely for 1 minute to bypass the PIR motion circuit. 3. Have a qualified technician verify 120V AC at the junction box wire nuts. If 120V AC is present and covering the photocell produces no light, the potted AC-DC driver or series LED array has failed.
Verified Replacement Parts
Internal AC-DC Constant-Current LED Driver Board
Proprietary internal power supply potted in solid resin inside the central canopy; no OEM spare part is sold and unsafe aftermarket substitution is prohibited.
Articulated Lamp Head Assembly (Graphene + PA66 Shell, 28-LED MCPCB, PC Diffuser)
Permanently wired through friction swivel knuckles and ultrasonically sealed; not available as a modular spare part.
Closed-Cell EVA Canopy Weatherproofing Backplate Gasket
Passive exterior perimeter compression barrier between the mounting canopy and wall junction box; safe to match or cut from closed-cell EVA/neoprene sheet.
Why This Happens & Safety Warnings
- Always turn off circuit breaker power before installing, inspecting, or servicing branch wiring; never touch energized wiring.
- Do not attempt to open, modify, or repair internal electronics or sealed LED lamp heads; internal assemblies contain no user-serviceable parts.
What triggers it: Prolonged operation at 85W line draw, especially continuous 8-to-12-hour overnight operation in Dusk-to-Dawn mode or warm climates.
What wears out inside: Sustained internal heat within the unventilated polymer canopy gradually evaporates liquid electrolyte inside the potted AC-DC switch-mode driver's smoothing capacitors, elevating equivalent series resistance (ESR) and destabilizing the constant-current regulation loop.
Symptom on machine: Stroboscopic flickering, severe lumen drop, or complete driver shutdown requiring whole-fixture replacement due to potted non-serviceable construction.
What triggers it: Sudden cold rainstorms quenching hot 85W operating lamp heads, or rainwater tracking down rough exterior wall siding against an uncaulked canopy gasket.
What wears out inside: Rapid thermal contraction of internal air inside the sealed lamp shells creates a partial vacuum that draws rainwater past aged silicone knuckle O-rings, while gaps in the rear EVA foam gasket allow water into the junction box cavity.
Symptom on machine: Internal lens fogging/water pooling, electrochemical corrosion of MCPCB copper traces and SMD solder joints, or upstream GFCI breaker tripping.
Cross-Compatible Platforms: Legal manufacturer: Dong Guan Shi You Liang Dian Zi You Xian Gong Si (Dongguan, China); FCC Grantee Code 2BCKN