Abovizo AB22: Fixture Remains Continuously Illuminated (Stuck On)
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Floodlight stays illuminated continuously during daytime or fails to shut off after the TIME delay expires in Motion Sensor mode.
02 // Non-Invasive Meter / Bench Verification
1. Verify whether the mode switch is set to Dusk-to-Dawn (D2D) rather than Motion Sensor mode. 2. Check the LUX rotary dial (turning toward 2000 LUX enables daytime operation) and TIME dial (up to 10-minute hold). 3. Inspect the 180° field of view for continuous heat sources (HVAC exhaust vents, moving foliage, street traffic). 4. Cover the sensor lens completely in Motion mode; if the light still never turns off after 10 minutes, internal switching relay/TRIAC contact welding or photocell failure is implicated.