Symptom Guide Model: FG-1625

Honeywell FG-1625: Red Alarm LED Remains Continuously Illuminated After Alarm Event

What this means: The red Alarm LED stays latched ON indefinitely following a qualified acoustic event while the Form A alarm relay automatically resets after 5.0 seconds.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Clapping hands loudly in front of the sensor causes the green Event LED to flicker briefly, but does not illuminate the red Alarm LED or open the Form A alarm relay loop. — The hand-clap feature is designed solely to verify that 12 VDC power is present and that the electret microphone and preamplifier stage are responsive. The FlexCore ASIC requires concurrent multi-domain qualification (low-frequency structural impact flex wave plus 10-15 kHz glass fracture harmonics) to trip the Form A relay; full alarm testing requires placing the unit into Test Mode and using a calibrated Honeywell FG-701/FG-700 simulator.

Confirm DIP switch S3 (LATCH) is set to ON. Reset the latched LED memory by momentarily cycling auxiliary power at the panel or toggling the detector into and out of Test Mode.

2

Verified Replacement Parts

#1 Most Likely Fix Approx. $50.99

Complete Replacement Honeywell IntelliSense FG-1625 Peripheral Assembly

0-001-027-01 Copy Part #

Exact OEM SKU replacement required upon board-level surge damage, solid-state relay burnout, contaminated microphone capsule, or broken ABS housing.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in hardwired acoustic glassbreak sensor replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • End users are instructed not to open the enclosure or modify terminal wiring to avoid causing panel trouble alerts or compromising perimeter security.
  • Do not remove the printed circuit board (PCB) from the ABS plastic baseplate; improper reseating compromises the calibrated acoustic isolation channel surrounding the microphone.

Cross-Compatible Platforms: Model FG-1625T (0-001-027-02) shares identical FlexCore acoustic signal processing, housing geometry, and 25 ft range, but adds Form C (SPDT) relay contacts and cover/wall mechanical tamper switches.

Other Honeywell FG-1625 Problems (3)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...