Symptom Guide Model: FG-1625

Honeywell FG-1625: Synchronous Blinking / Flashing of Red Alarm LED and Green Event LED

What this means: Indicates auxiliary DC bus input voltage at terminals V+ and V- has dropped below the 6.0 VDC minimum operational cutoff threshold, activating the internal low-voltage comparator.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Clapping hands loudly in front of the sensor causes the green Event LED to flicker briefly, but does not illuminate the red Alarm LED or open the Form A alarm relay loop. — The hand-clap feature is designed solely to verify that 12 VDC power is present and that the electret microphone and preamplifier stage are responsive. The FlexCore ASIC requires concurrent multi-domain qualification (low-frequency structural impact flex wave plus 10-15 kHz glass fracture harmonics) to trip the Form A relay; full alarm testing requires placing the unit into Test Mode and using a calibrated Honeywell FG-701/FG-700 simulator.

Observe dual LED flash pattern through the front window; verify whether the host alarm control panel is experiencing AC utility loss, depleted standby battery, or overloaded 12 VDC auxiliary power bus.

Target: 6.0 VDCTarget: 12 VDC
2

Verified Replacement Parts

#1 Most Likely Fix Approx. $50.99

Complete Replacement Honeywell IntelliSense FG-1625 Peripheral Assembly

0-001-027-01 Copy Part #

Exact OEM SKU replacement required upon board-level surge damage, solid-state relay burnout, contaminated microphone capsule, or broken ABS housing.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in hardwired acoustic glassbreak sensor replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • End users are instructed not to open the enclosure or modify terminal wiring to avoid causing panel trouble alerts or compromising perimeter security.
  • Do not remove the printed circuit board (PCB) from the ABS plastic baseplate; improper reseating compromises the calibrated acoustic isolation channel surrounding the microphone.
Auxiliary DC Bus Voltage Brownout Comparator Lockup (< 6.0 VDC)

What triggers it: Host alarm control panel battery depletion during extended AC utility outage, excessive voltage drop across long 18-22 AWG wire runs, or overloaded panel auxiliary power bus (exceeding panel current budget with 12 mA standby / 22 mA alarm draw per unit).

What wears out inside: Input voltage at V+ and V- drops below the 6.0 VDC minimum operating threshold of the internal linear regulator, tripping the hardware under-voltage comparator.

Symptom on machine: Sensor enters a forced low-voltage fault state, de-energizing and opening the Form A normally closed alarm relay loop and causing persistent zone trouble/alarm faults on the host panel keypad.

Cross-Compatible Platforms: Model FG-1625T (0-001-027-02) shares identical FlexCore acoustic signal processing, housing geometry, and 25 ft range, but adds Form C (SPDT) relay contacts and cover/wall mechanical tamper switches.

Other Honeywell FG-1625 Problems (3)
1. Quick Test 2. See Fix Parts ↓