SimpliSafe GB3000: Glassbreak Sensor Offline
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Official telemetry alert displayed in the SimpliSafe Mobile App indicating the Base Station has missed expected supervisory check-in transmissions from the Glassbreak Sensor.
02 // Non-Invasive Meter / Bench Verification
1. Verify and update Base Station firmware to 2.21.4.6 or newer via the SimpliSafe app or Keypad. 2. Slide the sensor off its bracket and replace the 3V CR123A lithium battery. 3. Place the system in Keypad Test Mode and press the top button on the sensor. 4. If the sensor was offline for an extended period and remains offline after battery replacement, remove the device in the SimpliSafe app (My System -> Device Settings -> Remove Device) and re-pair it.
Platform / OEM Cross-Reference: Compatible exclusively with SimpliSafe Gen 3 Base Stations (U9K-BS3000, U9K-BS3001, U9K-BS3010) alongside sibling 3000-series sensors (SSES3, SSMS3, WT3000, FS3000, PB3000).