⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

When the system is in Keypad Test Mode and the top sensor button is pressed, a loud hand clap near the target window fails to flash the front LED or trigger the Base Station 'Glassbreak Sensor' voice confirmation.

02 // Non-Invasive Meter / Bench Verification

Confirm the Keypad is actively in Test Mode and that the top button on the Glassbreak Sensor was pressed immediately prior to clapping. Verify unobstructed line-of-sight (< 20 ft unobstructed, or 5 to 10 ft / < 6 ft with heavy curtains), check CR123A battery insertion/tab removal, and adjust the rear sensitivity slider if needed.

Platform / OEM Cross-Reference: Compatible exclusively with SimpliSafe Gen 3 Base Stations (U9K-BS3000, U9K-BS3001, U9K-BS3010) alongside sibling 3000-series sensors (SSES3, SSMS3, WT3000, FS3000, PB3000).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
Duracell CR-123A CR123A 3V Primary Lithium Battery Cell
Explicitly specified in official SimpliSafe manuals and support battery guides. Do not substitute 3.7V nominal (4.2V peak) 16340 / RCR123A rechargeable Li-ion cells without verifying over-voltage tolerance.
OEM Spec (Duracell): $3–$6 / Generic Industrial: $2–$4
Part 2
oem replacement part
Isolated Match
SSGB3 Complete SimpliSafe Gen 3 Glassbreak Sensor Assembly
Proprietary SimpliSafe Gen 3 433.92 MHz FSK peripheral; no third-party glassbreak sensor (such as Vivint GB3000-345 or Honeywell 5853) or legacy SimpliSafe GB1000 can pair with the Gen 3 Base Station.
OEM Retail: $39.99 ($29–$40 retail range; $0 under 1-Year Limited or Subscription Lifetime Warranty)
Part 3
routine consumable
Isolated Match
Double-Sided… Double-Sided Foam Wall Mounting Adhesive Strips
Matches factory pre-applied foam pad footprint on the rear slide-off bracket; requires wall surface degreasing with rubbing alcohol (IPA), complete drying, and 30-second press.
OEM: Included in box / Generic: $4–$7 per pack
Part 4
accessory
Isolated Match
2x #4 or #6 x 3/4 in.… Permanent Wall Mounting Screws (2x)
Official installation guide specifies peeling adhesive off the mounting plate and securing the bracket with the 2x Phillips screws for permanent retention.
OEM: Included in box / Generic: < $2
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified wireless acoustic glassbreak intrusion sensor replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopperSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not expose the sensor to direct water or operate in wet environments (> 90% RH); indoor dry-location use only.
  • Remove the CR123A battery from any sensor whose activation tab has been pulled prior to shipping for a 60-day return or warranty RMA.

Root Failure Mechanism: Supervisory Telemetry Link Dropout (Glassbreak Sensor Offline / Sensor Not Responding)Click to spotlight part ↑

01 // Trigger ConditionDepletion of the 3V CR123A battery over 1 to 3 years, placement within 3 to 5 feet of RF/EMI emitters, sub-freezing temperatures (< 32°F), or Base Station operating on firmware older than 2.21.4.6.
02 // Degradation PhysicsInsufficient 3V rail voltage, 433.92 MHz FSK packet collision/attenuation, or Base Station supervisory table desynchronization prevents scheduled heartbeat check-ins from reaching the Base Station.
03 // Lockout / ImpactLoss of acoustic intrusion monitoring for the assigned window zone until the battery is replaced, RF interference is cleared, or Base Station firmware is updated.

Root Failure Mechanism: Acoustic False-Negative (Missed Window Break Detection Due to Heavy Drapery Standoff or Laminated Glazing)Click to spotlight part ↑

01 // Trigger ConditionSensor mounted > 20 ft from unobstructed windows, > 5 to 10 ft (> 6 ft US quick-start) from windows covered by heavy curtains, or deployed to monitor laminated/anti-smash security glass.
02 // Degradation PhysicsFree-field inverse-square attenuation, textile absorption of kilohertz glass-shatter overtones by heavy draperies, or damping of brittle fracture emissions by laminated PVB interlayers prevents the acoustic signal at the microphone port from satisfying the dual-stage DSP gate.
03 // Lockout / ImpactFailure to trigger an alarm during an actual forced-entry glass break event.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Sensor does not trigger an alarm when the user claps their hands in Armed mode or plays YouTube/phone audio recordings of breaking glass.: In normal Armed (Home or Away) operation, the sensor requires a sequential two-stage physical acoustic signature: (1) a low-frequency infrasonic/structural pressure wave ('thump') from an exterior window pane being struck inward to wake the comparator, followed microseconds later by (2) high-frequency brittle glass shatter overtones. Smartphone and TV speakers cannot reproduce the structural low-frequency window thump, and hand claps only trigger the sensor when the system is placed in Keypad Test Mode and the top sensor button is pressed (which temporarily lowers the threshold to respond to all loud sounds). (True fault when: Indicates a placement or hardware issue only if the sensor also fails to flash its front LED and announce 'Glassbreak Sensor' on the Base Station when clapping after pressing the top button inside official Keypad Test Mode.)
False-Alarm Check — Sensor does not trigger an alarm when a ceramic dinner plate, bowl, or drinking mug drops and shatters on the floor.: The onboard DSP is explicitly programmed to differentiate the resonant acoustic frequency spectrum and preceding structural frame thump of a window pane shattering from the acoustic decay profile of ceramic dinner plates or thick mugs breaking. (True fault when: Not a fault; verify actual window acoustic path using the official Keypad Test Mode clap procedure.)