01 // Observed Condition
Failure of a door/window contact event to trigger the central siren due to magnet misalignment (> 1 cm), depleted sensor battery, or 433.92 MHz RF attenuation/interference.
02 // Non-Invasive Meter / Bench Verification
Separate the door sensor magnet and watch the sensor's red LED indicator: (1) If the LED does not flash, verify the closed magnet alignment gap was < 1 cm and replace the 23A 12V or CR2032 battery; (2) If the red LED flashes upon opening but the hub does not respond, bring the sensor next to the hub to test pairing and verify whether indoor distance (> 15-30 m) or RF interference blocked the 433.92 MHz signal.
Platform / OEM Cross-Reference: Towode alarm hardware shares direct OEM manufacturing provenance, PCB layouts, and firmware procedures with Shenzhen Kerui Smart Technology Co., Ltd. (KERUI).