FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: DLSJ TIER 1–2 BENCH DIY

Towode DLSJ: PIR motion sensor triggers alarm with no human intruder present

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Unintended motion alarm broadcast caused by rapid infrared thermal shifts (sunlight, HVAC drafts, radiators) or pets exceeding the 12-25 kg thermal mass threshold across the Fresnel lens zones.

02 // Non-Invasive Meter / Bench Verification

Inspect sensor sightlines for windows, direct sunlight, HVAC vents within 1-2 meters, or pet traffic. Relocate the PIR sensor to 2.0-2.2 m height facing an interior corner away from thermal sources and re-test.

Platform / OEM Cross-Reference: Towode alarm hardware shares direct OEM manufacturing provenance, PCB layouts, and firmware procedures with Shenzhen Kerui Smart Technology Co., Ltd. (KERUI).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
Isolated Match
Generic 433.92 MHz… Expansion or Replacement Wireless RF Sensor (Door/Window or PIR)
Hub EEPROM supports pairing up to 30-50 sensors using the standard 433.92 MHz EV1527 OOK learning protocol.
$4 - $12
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified smart home security alarm systems replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopperEepromSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not clean the PIR HDPE Fresnel lens with solvents, ammonia, or abrasive cleaners; use only a soft, dry microfiber cloth.
  • Do not interrupt power during Tuya Smart app OTA firmware updates, as this risks bricking the CB2S Wi-Fi module.

Root Failure Mechanism: False PIR Motion Intrusion Alarms from Thermal Drafts, Sunlight, or Optical DegradationClick to spotlight part ↑

01 // Trigger ConditionPIR sensor installed facing direct sunlight, windows, or within 1-2 m of HVAC vents/heaters, exposed to pets > 12-25 kg, or cleaned with prohibited chemical solvents.
02 // Degradation PhysicsMoving thermal air masses or creeping solar rays create 7-14 μm infrared differentials across the alternating HDPE Fresnel lens zones, exceeding the ΔT threshold of the RE200B sensor and BISS0001 analog comparator (or solvent clouding permanently distorts IR transmission).
03 // Lockout / ImpactRepeated nuisance 115-120 dB siren activations and false intrusion push notifications, or degraded detection sensitivity if the lens is chemically clouded.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Hub shows 'Offline' in the Tuya Smart / Smart Life app and fails to send smartphone push notifications, yet triggering a door or PIR sensor still sounds the local siren.: The local alarm state is governed by the independent TuyaMCU and 433.92 MHz receiver, while cloud connectivity relies on the 2.4 GHz-only CB2S (BK7231N) module. Dual-band routers using 5 GHz band-steering or expiring DHCP leases disconnect the 2.4 GHz SoC without affecting local 433.92 MHz alarm operation. (True fault when: Indicates a hardware or firmware fault (such as OTA bricking) only if the hub cannot enter EZ/AP pairing mode or fails to connect to an isolated, dedicated 2.4 GHz SSID at close range (RSSI stronger than -70 dBm).)
False-Alarm Check — PIR motion sensor triggers the alarm when no human intruder is in the room.: Passive infrared sensors (RE200B + BISS0001) do not recognize human shapes; they detect rapid changes in 7-14 μm infrared thermal energy across alternating Fresnel lens zones. Warm/cold air blasts from HVAC vents (within 1-2 m), direct sunlight moving across floors, or pets exceeding the 12-25 kg thermal mass threshold legitimately satisfy the analog comparator. (True fault when: Indicates a sensor fault only if false triggers persist after the sensor is placed in a closed, dark, thermally stable interior environment with no pets or airflow.)

Other Towode DLSJ Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...