Symptom Guide Model: Ultra-IN

ImoLaza Ultra-IN: Red flashing LED / Controller shuts down

What this means: Indicates an overcurrent condition on a zone output, typically due to a shorted external 24VAC solenoid coil or a damaged buried field wire.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Silent operation; slight warmth near internal transformer; brief relay/valve click outdoors. — The controller uses solid-state switching (TRIACs) which operate silently, unlike mechanical relays. The built-in transformer generates low continuous standby heat, which is normal. External solenoid valves will produce a brief click when actuated.

Unplug unit for 30 seconds, reconnect. Run each zone manually for 10 seconds via the physical buttons or app. If the unit trips on a specific zone, inspect/replace that zone's external solenoid valve (normal coil resistance ~20–60 Ω) and associated wiring.

Target: 24VACTarget: 20–60 Ω
2

Verified Replacement Parts

#1 Most Likely Fix $15–$35 each

24VAC Solenoid Valves (External)

Standard 24VAC 60Hz… Copy Part #

Compatible with standard 24VAC irrigation systems. Ensure proper voltage and current ratings.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in L13 smart wifi sprinkler controllers replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Zone Short-Circuit Shutdown

What triggers it: Activation of a specific irrigation zone.

What wears out inside: Buried field wire insulation nicked/damaged or external 24VAC solenoid coil internally shorted, leading to overcurrent condition (>1000mA).

Symptom on machine: Controller flashes red LED, shuts down the affected zone, or the entire unit, preventing irrigation.

Cross-Compatible Platforms: Intelligent Watering Decision Model™ (ET Smart Schedule, New Grass Schedule up to 24 start times, Fixed Schedule, up to 16 schedules, 99-minute max zone duration, sunrise/sunset offset).

Other ImoLaza Ultra-IN Problems (3)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...