FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: Ultra-IN TIER 4 LICENSED / SEALED

ImoLaza Ultra-IN: Solid/blinking yellow indicator light

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Indicates the controller is connected to Wi-Fi but has no internet access, or has lost its connection to the cloud server.

02 // Non-Invasive Meter / Bench Verification

Verify 2.4GHz SSID (not 5GHz) on the router. Power-cycle the router and then the controller (30-second disconnect). Check Wi-Fi signal strength at the exterior wall. Schedules will continue to run locally via RTC.

Platform / OEM Cross-Reference: Intelligent Watering Decision Model™ (ET Smart Schedule, New Grass Schedule up to 24 start times, Fixed Schedule, up to 16 schedules, 99-minute max zone duration, sunrise/sunset offset).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Complete Controller Unit Complete Controller Unit
Proprietary cloud-connected controller; no board-level OEM spare parts catalog published.
~$129.00 (seed)
Part 2
universal aftermarket part
Isolated Match
Standard 24VAC 60Hz… 24VAC Solenoid Valves (External)
Compatible with standard 24VAC irrigation systems. Ensure proper voltage and current ratings.
$15–$35 each
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified L13 smart wifi sprinkler controllers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSCopperEPDMEepromSiliconeTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: Wi-Fi Disconnect / Offline StateClick to spotlight part ↑

01 // Trigger ConditionExterior mounting location with RF attenuation, router reboot, or ISP outage.
02 // Degradation PhysicsLoss of 2.4GHz Wi-Fi signal strength or network connectivity, leading to lost DHCP lease or cloud server link.
03 // Lockout / ImpactController displays yellow LED, loses cloud ET weather sync, app control, and push notifications. Local schedules continue via RTC.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Silent operation; slight warmth near internal transformer; brief relay/valve click outdoors.: The controller uses solid-state switching (TRIACs) which operate silently, unlike mechanical relays. The built-in transformer generates low continuous standby heat, which is normal. External solenoid valves will produce a brief click when actuated. (True fault when: Excessive heat from the transformer, smoke, or burning smell would indicate a fault. Absence of external valve clicks when a zone is active may indicate a valve or wiring fault.)

Other ImoLaza Ultra-IN Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...