MHCOZY ZG2CH5-220V: Relay clicks and LED toggles, but connected load does not turn on.
What this means: The internal relay coil is energizing, but the external circuit connected to the dry contacts is not completing or receiving power.
60-Second Verification Check
Verify external load power is routed in series through COM and NO terminals. Check external load power supply and wiring. Remember outputs are dry contacts (zero voltage).
Verified Replacement Parts
5V 10A SPDT PCB Cube Relay
Standard electromechanical relay with matching coil voltage, contact rating, and pinout.
Why This Happens & Safety Warnings
- Manufacturer explicitly notes the AC 85–250V input is non-isolated and recommends USB 5V power or professional enclosure installation.
- Opening/modifying the enclosed variant or altering board circuitry voids seller warranty coverage.
What triggers it: Switching inductive loads (motors, compressors, ballasts) or resistive loads exceeding 10 A.
What wears out inside: High inrush currents and arcing across miniature silver-alloy contacts cause material transfer, pitting, and eventual welding (contacts stuck closed) or erosion (contacts fail open).
Symptom on machine: Relay fails to switch the load, remaining permanently on or off, requiring replacement.
Cross-Compatible Platforms: Non-isolated AC 85–250V input safety advisory