Symptom Guide Model: ZG2CH5-220V

MHCOZY ZG2CH5-220V: Turning on Channel 2 immediately turns off Channel 1 (or vice versa).

What this means: The module is operating in 'Interlock' mode, where only one channel can be active at a time.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Audible mechanical click from the module when a relay is activated/deactivated. — This is the normal sound of the internal SPDT electromechanical relays energizing and de-energizing their coils to switch the dry contacts.

Press the Mode Switch button to cycle through modes until 'Self-Locking' (independent operation) is restored.

2

Verified Replacement Parts

#1 Most Likely Fix ~$20–$44 USD

Complete 2CH Zigbee Dry-Contact Module

ZG2CH5-220V Copy Part #

Direct replacement for the SKU.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in in wall micro relays dry contacts replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Manufacturer explicitly notes the AC 85–250V input is non-isolated and recommends USB 5V power or professional enclosure installation.
  • Opening/modifying the enclosed variant or altering board circuitry voids seller warranty coverage.
Accidental Mode Misconfiguration (Interlock/Inching)

What triggers it: Inadvertent or uninformed press of the hardware Mode Switch button during installation or operation.

What wears out inside: The global mode setting is changed from 'Self-Locking' (independent channels) to 'Interlock' (mutually exclusive) or 'Inching' (momentary), leading to unexpected relay behavior.

Symptom on machine: Connected loads (e.g., lights, garage doors) operate unexpectedly or fail to respond as intended.

Cross-Compatible Platforms: Non-isolated AC 85–250V input safety advisory

Other MHCOZY ZG2CH5-220V Problems (2)
1. Quick Test 2. See Fix Parts ↓